THE PREVALENCE, SOME ASSOCIATION FACTORS TO MONITORING AMONG TERM-PREGNANCIES WITH MECONIUM-STAINED AMNIOTIC FLUID AT CAN THO GYNECOLOGY AND OBSTETRICS HOSPITAL

Thanh Thuy Nguyen 1, , Kim Dung Huynh1
1 Can Tho Gynecology and Obstetrics Hospital

Main Article Content

Abstract

Background: Meconium-stained amniotic fluid (MSAF) is dangerous to the fetus, even affecting the development of the child after birth if not detected and treated promptly. Objectives: Determining the rate of term-pregnancies with meconium-stained amniotic fluid and their characteristics of obstetrics monitoring; discovering the association between obstetrics monitoring and meconium-stained amniotic fluid. Materials and method: A descriptive cross-sectional study on 315 term-pregnancies in labor at Can Tho Gynecology and Obstetrics Hospital from April 2020 to September 2020, of which had 50 with MSAF. Results: The incidence of pregnant women with MSAF was 15.9%. The average age was about 29.4 ± 5.6. The mean gestational age was 38.8 ± 0.75 weeks. 52% of women with MSAF had normal variability, low variability (≤5 beats per minute) increased the risk of MSAF by 7.7 times (p=<0.001), high variability (>25 beats per minute) increased the risk by 6 times (p=0.004). Group 2 tracings increased the risk of MSAF by 6.48 times, group 3 increased the risk of MSAF by 25.5 times (p <0.05). Conclusions: Variability of cardiotocography (CTG) is a high valuable factor for monitoring fetal health in labor. 

Article Details

References

1. Bộ Y tế (2016), “Suy thai cấp”, Hướng dẫn quốc gia về các dịch vụ chăm sóc sức khỏe sinh sản, Bộ Y tế, Hà Nội, tr.128.
2. Nguyễn Thị Kim Hoàng (2005), "Mối tương quan của Monitoring sản khoa trong chuyển dạ với tiên lượng sức khoẻ sơ sinh", Luận văn chuyên khoa cấp II, Đại học Y Dược thành phố Hồ Chí Minh.
3. Lê Nguyễn Thuỳ Nhân (2017), "Nghiên cứu đặc điểm lâm sàng, cận lâm sàng và kết quả cuộc sinh của thai phụ chuyển dạ có nước ối xanh tại Bệnh viện Phụ sản thành phố Cần Thơ năm 2016-2017", Luận văn tốt nghiệp bác sĩ đa khoa, Đại học Y Dược Cần Thơ.
4. Hoàng Bảo Nhân, Nguyễn Vũ Quốc Huy (2013), "Kết quả kết thúc thai kỳ ở thai phụ đủ tháng có nước ối lẫn phân su", Tạp chí Phụ sản, 11(1), 22-31.
5. American College of Obstetricians and Gynecologists (2009), “Intrapartum Fetal Heart Rate Monitoring”, Obstetrics & Gynecology,114 (1), July 2009.
6. Cunningham F.R., et al. (2018), "Fetal Imaging", "Fetal Assessment", Williams obstetrics 25th, McGraw-Hill, USA, pp. 331-345,457-484.
7. Dagne Addisu, et al. (2018), "Prevalence of meconium stained amniotic fluid and its associated factors among women who gave birth at term in Felege Hiwot comprehensive specialized referral hospital, North West Ethiopia: a facility based cross-sectional study," BMC Pregnancy Childbirth, p. 429.
8. Dharna S. Desai, et al (2017), “ Fetal heart rate patterns in patients with thick meconium staining of amniotic fluid and its association with perinatal outcome”, International Journal of Reproduction, Contraception, Obstetrics and Gynecology;6(3):1030-1035.
9. Kyung A Lee,et al. (2011), “The frequency of meconium-stained amniotic fluid increases as a function of the duration of labor”, The Journal of Maternal-Fetal and Neonatal Medicine, July 2011; 24(7): 880–885.
10. Liran Hiersch, et al. (2016), “Meconium-Stained Amniotic Fluid and Neonatal Morbidity in Low-Risk Pregnancies at Term: The Effect of Gestational Age”, American Journal of Perinatology 2017; 34(02): 183-190.
11. Ramya Sundaram, et al. (2016), “Risk factors for meconium staining of amniotic fluid and ít implications”, Int J Reprod Contracept Obstet Gynecol; 5(8), pp.2503-2506.
12. Samiyappa DP, et al. (2016), “Maternal and perinatal outcome in meconium stained amniotic fluid at term:a case controlstudy”, Int J Reprod Contracept Obstet Gynecol; 5(10),pp 3404-3410.
13. Vanesa R. F, et al. (2018), “Intrapartum and perinatal results associated with different degrees of staining of meconium stained amniotic fluid”, European Journal of Obstetrics and Gynecology and Reproductive Biology, S0301- 2115(18)30127-1.